product detail:
YUKEN SERIES EDBG proportional controls valve
Instructions
Applicable Power Amplifiers
For stable performance, it is recommended that Yuken's applicable power amplifiers be used (for details see Catalogue
No. Pub. EC-1305).
When ordering the EFBGM-10Y, see Type F3 Pipe Flange Kits on the Catalogue No. Pub. EC-3001 and order an appropriate pipe flange kit also.
Drain Back Pressure
Check that the drain back pressure dose not exceed 0.2 MPa (29 PSI).
When Relief Valve Passing Flow Rate is Low in Pressure Control State
To avoid preselected pressure instability, use a passing flow rate of 15 L/min (4.0 U.S.GPM) or higher.
Further, check that the tank-line back pressure dose not exceed 0.5 MPa (70 PSI).
No.34
Safety Valve Pressure Setting
The pressure of the safety valve is preset at the value equal to the upper limit of the pressure adjustment range plus
2 MPa (290 PSI). Please adjust the pressure of the valve so preset to meet the pressure to be used actually.
To lower the pressure setting, turn the safety valve pressure adjustment screw anti-clockwise. After adjustment, be sure
to tighten the lock nut.